OCT file formats Voxelis opens
For education and personal viewing; not for diagnosis. Voxelis is not a medical device, is not FDA-cleared or CE-marked, and must not be used for clinical decisions. Every image in the app carries a “Not for diagnosis” mark. If you have questions about your own scan, ask the professional who ordered it.
Voxelis opens OCT studies in DICOM format, and the export files of several eye scanners directly. An export is converted to standard ophthalmic DICOM on your device when you import it; nothing is uploaded, and there is no account.
| Format | Extension | Written by |
|---|---|---|
| Topcon .fda | .fda | Topcon 3D OCT-1000 and 3D OCT-2000; Topcon Maestro; Topcon Triton |
| Topcon .fds | .fds | Topcon 3D OCT-1000; Topcon 3D OCT-2000 |
| Heidelberg .e2e | .e2e, .sdb | Heidelberg Spectralis, exported from Heidelberg Eye Explorer (HEYEX) |
| Heidelberg .vol | .vol | Heidelberg Spectralis, exported from Heidelberg Eye Explorer (HEYEX) as raw data |
| Zeiss Cirrus .img | .img | Zeiss Cirrus HD-OCT (raw scan export) |
| Optopol .opt | .opt | Optopol REVO, exported from SOCT |
| Bioptigen .oct | .oct | Bioptigen SD-OCT systems; Leica Envisu |
Each page explains what the format is, how to open it step by step and what the file does and does not record.
Not supported
- Optovue
.oct(with its.txtdescription file) is not supported in the App Store version of Voxelis: its reader has not yet been checked against a file from a device. - Photos of a display, PDF reports and printouts are not scanner exports and do not open as OCT scans.
What Voxelis shows for OCT
- Scroll through the B-scans; zoom and measure in µm or mm when the file records the pixel size, otherwise in pixels.
- When the file records where each B-scan lies on the fundus image (for example Heidelberg .vol, and DICOM OCT studies that include it), the fundus image shows those scan positions; tap a line to go to that B-scan. Each format page says whether its files do.
- Retinal layer lines stored in the file by the device (Heidelberg, Topcon, Optopol), or experimental lines computed on your device, each with an on-image caption that marks them not for diagnosis.
- A thickness cursor and a height caliper that snaps to the layer lines.
- En-face views of the retina and an ETDRS grid with sector means and macular volume when the file records its spacing.
- The eye (OD or OS) only when the file itself states it.
Voxelis runs on iPhone and iPad, and on a Mac with Apple silicon. Some features are part of Voxelis Pro, an optional in-app purchase.
Many files at once on a Mac
To turn a folder of scanner exports into standard DICOM files on a Mac, with patient details replaced by study codes, see OCT Convert, a separate Mac utility by the same developer.